Allows suction access without disconnecting
circuits;
provides catheter access to instill surfactant
B&B NEO2-SAFE Infant Ventilator Circuit Manifold with Suction
Port provides an interface between the ventilator circuit and
the endotracheal tube maintaining a closed circuit during various
procedures. The manifold fits all neonatal circuits. The suction
port consists of a Duckbill valve made of silicone. The manifold
is manufactured with a latex-free, hypo-allergenic material.
When infants are disconnected from the ventilator for specific
procedures, i.e., suctioning, many infants rapidly desaturate
due to the loss of positive end-expiratory pressure (PEEP) and
their inability to maintain FRC. A method to allow for suctioning
without disconnect from the ventilator circuit may prevent or
minimize this occurrence. The NEO2-SAFE valve used in line with
a 10 mm ventilator circuit allows access for suctioning without
disconnect from the ventilator effectively reducing the potential
for hypoxemia associated with open circuit suctioning. The NEO2-SAFE
maintains PEEP or CPAP during suction procedures.
The NEO2-SAFE manifold has an additional function, to provide
access via catheter insertion for instillation of surfactant.
A catheter can be passed into the infant’s endotracheal
tube without interruption of ventilation by passing the catheter
through the port on the NEO2-SAFE valve. The NEO2-SAFE Infant
Ventilator Circuit Manifold with Suction Port maintains a closed
airway circuit system by sealing the valve around the catheter.
Peer Reviewed articles support the effectiveness of the NEO2-SAFE
for suctioning and instillation of peripheral medication via catheter.
The NEO2-SAFE is intended for single patient use application
and should not be reused.
Convenient...
| |
|
| •
|
Adapts to Infant Ventilator Circuits (10 mm)/reusable
or single patient use
|
| • |
Easy access to the airway for suction procedure via
the Duckbill valve |
| |
|
|
Cost
Effective...
| |
|
| •
|
Dual purpose manifold (suction and medication instillation) |
| • |
Reduction of costs that can be associated with closed
suction catheter systems |
| |
|
|
Safe...
| |
|
| •
|
Enhanced durability of the Duckbill valve to maintain
ventilation and PEEP |
| • |
Latex Free Solution |
| • |
Hypoallergenic materials |
| |
|
|
Versatile...
| |
|
| •
|
Designed for use in the NICU, Labor & Delivery
and Transport |
| |
|
|
Ordering
Information:
11100 NEO2-Safe™ (100/case)
11103 NEO2-Safe™ Cap (100/case)
11105 NEO2-Safe™ (50/box) |
|