Safe, accurate method to deliver CPAP therapy
in neonatal critical care environments
The Babi.Plus Bubble PAP Valve 0 – 10 cm H2O provides a safe, convenient and
accurate method of delivering continuous positive airway pressure (CPAP) for use
with infants weighing < 10 kg. The PAP is adjustable from 1 to 10 cm H2O
with gas flow from 1 to 12 liters per minute with accuracy of +/- 1 cm of H2O.
The Babi.Plus Bubble PAP Valve has FDA (510k) market clearance for single
patient use delivery of positive end expiratory pressure in patients weighing
< 10 kg in hospital environments to increase end lung pressure above
atmospheric in a constant flow condition.
The patent-pending Babi.Plus Bubble PAP Valve’s ergonomic design allows
airway pressure to be easily set without the cumbersome and time consuming
tasks normally associated with bubble CPAP devices. The PAP valve is
installed at the end of the expiratory limb in a continuous gas flow system to
provide positive pressure within the breathing circuit. A 360 degree swivel inlet
connector accepts 15 mm OD and 22 mm ID expiratory circuit connectors.
A water level adjustment port allows fluid level to be easily maintained by
adding or removing fluid without disconnecting the circuit or loss of PAP. The
expiratory ports direct gas quietly away from clinicians.
Babi.Plus Bubble PAP Valve jar has an integrated ISO compliant equipment
mount. This feature makes it easy to secure the jar onto a standard equipment
pole with a single or custom dual pole clamp. The complementary Venti.Plus™
Single Pole Clamp and Venti.Plus Dual Pole Clamp are designed specifically to
pair with Babi.Plus products and also work well with other products requiring
pole clamps. The Venti.Plus pole clamps are available separately.
The Babi.Plus Bubble PAP Valve 0 – 10 cm H2O can be used in all neonatal
critical care units, delivery rooms and special procedure units.
Convenient...
| |
|
| • |
Complete package for delivery of CPAP therapy; ready for immediate set up in the NICU
|
| • |
Use with single or custom dual pole mounting clamp for positive attachment to standard equipment pole |
| • |
Custom dual pole mounting clamp minimizes need for additional pole clamps for humidifier system |
| |
|
|
Cost
Effective...
| |
|
| • |
Eliminates time-consuming tasks normally associated with assembly and maintenance of hospital assembled bubble CPAP devices |
| • |
Closed system minimizes the incidence of atmospheric fluid contamination |
| |
|
|
Safe...
| |
|
| • |
Accurate method to deliver CPAP for infants weighing < 10 kg |
| • |
Latex free, hypoallergenic material |
| • |
Clearly marked settings for precise PAP pressure adjustment |
| • |
Positive engagement, rotating pressure adjustment lever reduces risk of inadvertent setting changes |
| |
|
|
Versatile...
| |
|
| • |
CPAP is adjustable from 1 to 10 cm H2O |
| • |
Accepts 15 mm OD and 22 mm ID circuits |
| • |
Babi.Plus Bubble PAP Valve easily attaches to most standard pole systems
|
| |
|
|
Ordering
Information:
20205 Babi.Plus™ Bubble PAP Valve 0 – 10 cm H2O (12/box)
20210 Babi.Plus™ Bubble PAP Valve 0 – 10 cm H2O (24/case) |
|